Impulse 7010 除颤器可选负载附件 | | A unique, robust and easy-to-use tool to test defibrillators under a variety of patient impedance conditions. |
As you know the Impulse 7000 can do the following defibrillator performance tests:ECG functionality tests, AED or Shock Advisory capability tests, Pacemaker tests, and charge- and synch-time tests.But in order to test defibrillator-delivered energy values, you must have the 7010 Load Box. The Impulse 7000 and 7010 Load Box work together as a system to test more than one impedance load.In fact, it can replicate all possible human variations. The 7010 Load box replicates selectable impedance values and sends the energy values to the Impulse 7000.If you already have an Impulse 7000, you know it displays the delivered energy values and identifies the waveform type.It shows that the right current was delivered to the patient for a specific defibrillator setting, ensuring patient safety. In summary, the 7010 Load Box is a unique, robust and easy-to-use tool which provides the capability to test defibrillators under a variety of patient impedance conditions, and is the perfect companion to the Impulse 7000. |
特点 - Replicates all patient transthoracic impedance loads from infants to overweight adults
- Simulates user-selectable impedances as high as 200 ohms accuray
- Meets all defibrillator quality testing standards
|
| |
Impulse 7010 Defibrillator Selectable Load Accessory* (compatible with Impulse 7000 only) | 一般规格 | zui大电压 | 5000 V | zui大连续功率 | 12 W,相当于每 5 分钟 10 个 360 J 的除颤器脉冲 | 电感 | < 2 µH, @25 ?6?8 | | < 3 µH, @50 ?6?8 | | < 4 µH, @75 ?6?8 and 100 ?6?8 | | < 5 µH, @125 ?6?8 | | < 6 µH, @150 ?6?8 | | < 7 µH, @175 ?6?8 | | < 8 µH, @200 ?6?8 | 温度 | 工作温度:10 ºC 至 40 ºC(50 ºF 至 104 ºF) | | 存放:-20 ºC 至 60 ºC(-4 ºF 至 140 ºF) | 湿度 | 10 % 至 90 %,无冷凝 | 尺寸(宽x深x高) | 154 mm x 272 mm x 138.7 mm | | (6.07 in x 10.71 in x 5.46 in) | 重量(净重) | 1.54 kg (3 lb 6.2 oz) | 安全类 | 符合 EN61010-1 第二版,II 类产品 | 安全和 EMC 标志 | CE、CSA 和 C-Tick | 保修 | 两年延长保修(在福禄克医疗测试任何一家*服务中心进行首年校准后可免费享受延长保修) | 校准间隔 | 1 年 |
| 电气规格(同时适用于负载附件和分析仪) | 负载设置 | 25 ?6?8, 50 ?6?8, 75 ?6?8, 100 ?6?8, 125 ?6?8, 150, ?6?8, 175 ?6?8, and 200 ?6?8 ± 1 % | 精度 | 能量(除脉冲双相之外):2 % 读数 + 0.1 J,25、75 ?6?8 到 200 ?6?8 负载;1 % 读数 + 0.1 J,50 ?6?8 负载 | | 能量(脉冲双相):2.5 % 或读数 + 0.3 J,25、75 ?6?8 到 200 ?6?8 负载;1.5 1 % 读数 + 0.3 J,50 ?6?8 负载 | | 电压:1 % 读数 + 2 V,25 ?6?8 和 50 ?6?8 负载;2 % 读数 + 2 V,75 ?6?8 到 200 ?6?8 负载 | | 电流:2 % 或读数 + 0.1 A,25 ?6?8 负载;1 % 读数 + 0.1 A,50 ?6?8 到 200 ?6?8 负载 |
|
型号名称 | 描述 | Impulse 7010 | Impulse 7010 Defibrillator Selectable Load Accessory (*compatible with Impulse 7000 only) |
| |